锅炉带负荷在线清洗技术的探讨
[align=center]张文梅 任渊峰太原第二热电厂(山西 太原 030041)[/align]
[摘 要] 由于太原二电厂7#锅炉水冷壁管表面的严重腐蚀状况,沉积量超标,所以采用锅炉带负荷在线清洗技术,利用界面物理化学原理,清除受热面的垢和腐蚀产物。在经过两年的时间,采取在线保养清洗,启动过程保养性清洗,停运过程保养兼清洗联合除垢,其水冷壁管沉积量有所下降。
[关键词] 锅炉;在线清洗;带负荷清洗
[align=center]Discussion on techniques of boiler on-load cleaning
Zhang wenmei Ren yuanfeng
(Taiyuan Second Thermal Power Plant Shanxi Taiyuan 030041)[/align]
ABSTRACT:Because of 7# boiler water tubes surface has a serious corrosive condition and dregginess over standard in
Taiyuan Second Thermal Power Plant, using techniques of boiler on-load cleaning by boundary physical-chemical principle, cleaning
away furring and corrosion product of the heating surface. During two years, adopts on-line cleaning and protection, cleaning and
protection in the start-up, cleaning and protection in the lay-up, the dregginess of water wall tube has a little decreased.
KEY WORDS:boiler ; on-line cleaning;on-load cleaning
1 设备简介
太原第二热电厂#7 炉为东方锅炉厂生产的DG670/13.7-540/540-8 型超高压一次中间再热锅炉,于1994年1 月投产,炉内先采用全挥发处理,1998 年8 月改为低磷酸盐处理,2000 年7 月改为氢氧化钠处理。于1999 年8 月进行酸洗,工艺为盐酸清洗、柠檬酸漂洗、联氨钝化。
2003 年8 月大修水冷壁管割管检查,各水冷壁管都有大量针状有方向的鼓包,水冷壁管酸洗后,可以观察到布满针状或有皿状腐蚀坑,表面凹凸不平。向火侧沉积量达55.61g/m2。2006 年9 月甲侧水冷壁管沉积量:向火侧691.97g/ m2,背火侧207.08 g/ m2,水冷壁管沉积量超标。鉴于锅炉水冷壁管表面的严重腐蚀状况,采用化学清洗恐有相当大的风险,清洗过程存在发生穿管的可能性,所以选用更安全的清洗方法——锅炉带负荷在线清洗技术。
......
全文下载
[attach]1255[/attach]
页:
[1]