中国电厂化学网论坛's Archiver

ljy1946 发表于 2009-12-9 06:43

滨海电厂海水循环水系统中的电偶腐蚀与防护

[align=center]孟超。曲政
(钢铁研究总院青岛海洋腐蚀研究所,青岛266071)[/align]
摘要:电偶腐蚀是滨海电厂海水循环水系统中一种重要的腐蚀形式,结合深圳某滨海电厂5 机组海水循环水系统中发生的腐蚀情况,具体分析了腐蚀原因、影响因素及采取的保护措施和保护效果。
关键词:滨海电厂 循环水;电偶腐蚀
中图分类号:TG174.41 文献标识码:B
文章编号:1005—748X(2006)04—0187—04
[align=center]GALVANIC CORR0SION AND ITS PROTBCT10N 0F THE RECYCLING W ATER
SYSTEM IN A SEASHORE P0WER PLANT
MENG Chao,QU Zheng
(Central Iron& SteeI Research Institute Qingdao Research Institute for Marine Corrosion,Qingdao 266071,China)[/align]
Abstract:Galvanic corrosion is an important corrosion mode.The corrosion causes and influencing factors of the
recycling water system of Unit 5 in a seawater power plant in Shenzhen were analyzed.Impressed current cathodic
protection method was adopted and the protection effect was analyzed.
Key words:Seashore power plant;Recycling water;Galvanic corosion
    随着经济发展对电力的需求增加,自8o年代以来,在我国东部沿海地区新建了许多电厂。为了节约淡水资源,滨海电厂均采用海水作为循环冷却水,由于海水腐蚀性较强,而循环水系统是由多种材料、多种规格的管道及设备组成的复杂系统,由于不同材料间腐蚀电位的差异、材料的极化行为差异以及海水流动等因素的影响,使电偶腐蚀成为循环水系统中一种重要的腐蚀形式,造成材料、设备的腐蚀破坏和失效。
    本文结合深圳某滨海电厂5#机组海水循环水系统中发生的腐蚀情况,具体分析了腐蚀原因、影响因素及采取的保护措施。
......